Dimensions and Technical Information
ALARM
DURATION
SWITCH
ALARM VOLUME SWITCH (ON)
TRIP DELAY SWITCH (OFF)
(OFF)
(OFF)
JP4
JP3
(FACTORY DEFAULT SETTINGS)
Alarm Features Description
• Volume Switch JP2 - Sets alarm volume to high 105 dB or low 95 dB.
• Duration Switch JP3 and JP4 - Amount of time alarm sounds after trip. Arming
resets at end of duration if door is closed. Alarm will not reset if in continuous
mode; alarm sounds until battery is drained. Annunciator mode is a series of 10
short beeps or until door is closed.
• Trip Delay Switch JP5 - If you wish to ENTER an alarmed door without sounding
the horn immediately, the trip delay will allow 15 seconds for you to enter and
deactivate the alarm with the key switch before the alarm will sound.
• Arming Switch JP7 - This mode is useful when an AUTHORIZED EXIT is required
through alarmed door. In “ON” position immediate arming will set the alarm
ready to function as soon as door is opened. In “OFF” position delay arming will
allow 15 seconds for you to exit through the door without sending alarm signal.
JP2
JP5
ARMING SWITCH (ON)
FEATURES JP2 JP3 JP4 JP5 JP7
Volume - (105 dB) at 1 foot ON*
Volume - (95 dB) at 1 foot OFF
Duration - 30 second alarm OFF* OFF*
Duration - 180 second alarm OFF ON
Duration - Continuous alarm ON OFF
Duration - Annunciator mode ON ON
Trip - Immediate OFF*
Trip - 15 second delay ON
Arming - Immediate ON*
Arming - 15 second delay OFF
*Factory Settings
STOP STOP
COVER
STOP
EMERGENCY EXIT ONLY
ALARM SOUNDS WHEN DOOR IS OPENED
ON
OFF
JP7
19014 MOUNTING SCREW
(4) PROVIDED
TERMINAL BLOCK
FLANGES
BASE
SLOTS
SPECIFICATIONS
Housing 1/8 in. polycarbonate
Power Source 9 VDC alkaline
Sounder Output 95 dB - low
at 1 foot 105 dB - high
Relay Output 9 VDC, 40 mA
Dimensions 5.375 in. W x 5.375 in. H x 2 in. D
137mm x 137mm x 51mm
Standby Current 10 uA
Alarm Current 200 mA
TERMINAL STRIP
9 VOLT BATTERY
STOP
19011 TAMPERPROOF SCREW
(1) PROVIDED
19016 TAMPER WRENCH
(1) PROVIDED
45